Product Details:
Packaging Size | vial |
Manufacturer | Khandelwal Laboratories Pvt Ltd |
Brand | Lastet Injection |
Composition | Etoposide 100mg |
Packaging | vial |
Dosage Form | 100mg |
Treatment | Small cell lung cancer |
introduction of Lastte injection:
Lastet Injection is used to treat different cancers of lung, and testicles. It is also sometimes used to treat some other kinds of cancer in both men and women. It can be used on its own, or sometimes given together with certain other medicines as part of combination chemotherapy.
Lastet Injection is given as slow infusion into veins under the supervision of a healthcare professional and should not be self-administered. Your doctor will decide what dose is necessary and how often you need to take it. This will depend on what you are being treated for and may change from time to time. You should take it exactly as your doctor has advised. Taking it in the wrong way or taking too much can cause very serious side effects. It may take several weeks or months for you to see or feel the benefits but do not stop taking it unless your doctor tells you to.
USES OF LASTET INJECTION:
· Small cell lung cancer
· Testicular cancer
BENEFITS OF LASTET INJECTION:
1. In Small cell lung cancer
Small cell lung cancer is a fast-growing type of lung cancer commonly caused by smoking that starts with small tumors in the lungs but eventually spreads to the other parts of the body as well. Lastet Injection helps treat such types of cancer and may be given alone or in combination with other medicines. It is a potent and very toxic medicine and you should discuss the risks and benefits with your doctor. You should avoid drinking alcohol while having this treatment and drink plenty of water to stay hydrated.
2. In Testicular cancer
Testicular cancer is the cancer in the male organs called testicles that make male hormones and sperm. The testicles are located inside a loose bag of skin (scrotum) underneath the penis. Lastet Injection kills or stops the growth of cancer cells and also prevents the multiplication of cancer cells in men. It is given as an injection by a doctor or nurse and should not be self-administered.
mechanism of action of Lastte injection:Lastet Injection is an anti-cancer medication. It works by suppressing the activity of an enzyme (topoisomerase II) involved in DNA multiplication of the cancer cells. This slows the growth of cancer cells and eventually kills them.
Product Details:
Packaging Size | vial |
Brand | Gemcitabine(Gemolife NV 1000) |
Composition | GEMCITABINE 1000MG |
Manufacturer | Hetero Healthcare Limited |
Treatment | CANCER |
Prescription/Non prescription | Prescription |
Introduction of Gemolife NV 1000mg:
Gemolife NV 1000 Injection is utilized in the therapy of non-little cell cellular breakdown in the lungs, breast cancer, pancreatic cancer, urinary bladder cancer, and ovarian cancer.
Gemolife NV 1000 Injection is given as an infusion by a certified clinical expert. Your doctor will conclude what portion is essential and how frequently you want to take it. This will rely upon what you are being treated for and may change now and again. You ought to take it precisely as your doctor has prompted. Misinterpreting it in or taking an excessive amount of can cause intense aftereffects. It might require a little while or months for you to see or feel the advantages yet don't quit taking it except if your doctor tells you to.
Uses of gemolife NV 1000mg:
Advantage of gemolife NV 1000mg:
1. In Non-little cell cellular breakdown in the lungs:
Non-little cell cellular breakdown in the lungs is one of the significant sorts of cellular breakdown in the lungs and it influences the two smokers as well as non-smokers. Gemolife Nv 1000 Injection helps treat non-little cell cellular breakdown in the lungs and might be given alone or in mix with different meds. It is an intense and exceptionally harmful medication and you ought to examine the dangers and advantages with your doctor. You ought to abstain from drinking liquor while having this treatment and drink a lot of water to remain hydrated.
2. In Breast cancer:
Gemolife NV 1000 Injection assists with treating breast cancer and it could be utilized alone or in blend with different prescriptions or treatment modalities like chemotherapy. It lets the side effects free from breast cancer, for example, breast knots, ridiculous release from areolas or changes in the shape or surface of the breast. Gemolife Nv 1000 Injection kills or stops the development of cancer cells and furthermore forestalls the augmentation of cancer cells. Examine with your doctor assuming any of the secondary effects annoy you.
3. In Pancreatic cancer:
Pancreas are extremely fundamental for absorption of anything that you eat and furthermore for digestion of glucose levels as they produce the body's normal insulin. This medication will assist with controlling pancreatic cancer, and will alleviate the side effects, for example, absence of hunger or unexplained weight reduction. Gemolife Nv 1000 Injection assists with halting the activity of those synthetic compounds that guide in pancreatic cancer development and spread. It will assist you with carrying on with a more extended and better life.
4. In Urinary bladder cancer:
Urinary bladder cancer is the sort of cancer that creates in the bladder, typically in more seasoned grown-ups. The most well-known side effect of this cancer is blood in the pee. Gemolife Nv 1000 Injection is utilized in blend with different medications, for example, cisplatin to treat urinary bladder cancer that has progressed to later stages or even spread to different locales of the body (metastasized). It is an exceptionally viable medication and furthermore keeps the cancer from returning. In any case, you should examine the dangers and advantages of this medication prior to beginning your treatment.
Mechanism of action of Gemolife NV 1000mg:
Gemolife NV 1000 Injection obstructs the development of DNA and RNA of the cancer cells by subbing their structure blocks. It keeps the cancer cells from developing and increasing.
Product Details:
Packaging Size | vial |
Brand | Pemetrexed (PEMELIVE 500) |
Composition | PEMETREXED 500MG |
Manufacturer | ONCOBIOTEK |
Treatment | CANCER |
Prescription/Non prescription | Prescription |
Introduction of Pemgem 500mg Injection:
Pemgem 500mg Injection is utilized in the therapy of non-little cell cellular breakdown in the lungs and harmful pleural mesothelioma.
Pemgem 500mg Injection is given as an infusion by a certified clinical expert. Your doctor will conclude what portion is vital and how frequently you really want to take it. This will rely upon what you are being treated for and may change now and again. You ought to take it precisely as your doctor has prompted. Misinterpreting it in or taking a lot of can cause intense secondary effects. It might require a little while or months for you to see or feel the advantages yet don't quit taking it except if your doctor tells you to.
Uses of Pemgem 500mg Injection:
Benefits of Pemgem 500mg Injection:
Non-little cell cellular breakdown in the lungs is one of the significant sorts of cellular breakdown in the lungs and it influences the two smokers as well as non-smokers. Pemgem 500mg Injection helps treat non-little cell cellular breakdown in the lungs and might be given alone or in mix with different medications. It is an intense and extremely poisonous medication and you ought to examine the dangers and advantages with your doctor. You ought to abstain from drinking liquor while having this treatment and drink a lot of water to remain hydrated.
2.In Malignant pleural mesothelioma
Harmful pleural mesothelioma is a type of disease that creates in the lungs and the internal side of the ribs. It is an extremely forceful type of cellular breakdown in the lungs. Pemgem 500mg Injection is utilized alongside a few different medications to treat this disease. It kills the malignant growth cells, and forestalls the further duplication of disease cells. This limits the spread of disease to other unaffected regions. Adhere to your doctor's directions cautiously and counsel your doctor assuming you feel a little uncertain.
Mechanism of action of Pemgem 500mg Injection:
Pemgem 500mg Injection impedes the development of DNA and RNA of the malignant growth cells by subbing their structure blocks. It keeps the disease cells from developing and increasing.
Product Details:
Strength | 500mg |
Packaging Size | vial |
Composition | Tranexamic Acid 500mg |
Manufacturer | neon |
Dose | 5 ml |
Brand | neon |
Treatment | Treatment of Bleeding |
Prescription/Non prescription | Prescription |
Form | Injection |
Gender | Unisex |
INTRODUCTION OF KLOTIN 100 MG INJECTIONS:
Klotin 100mg Injection is utilized to treat dying. It assists with forestalling or lessen draining in conditions like tooth expulsion, weighty periods, broken uterine dying, nosebleed, and in any oral, prostate, or bladder medical procedure.
Klotin 100mg Injection is an enemy of fibrinolytic. It works by forestalling the breakdown of clumps which prompts the stoppage of dying. This infusion should be regulated under the management of a medical services proficient. You shouldn't accept it assuming you have any known sensitivity to this infusion.
USES OF KLOTIN 100 MG INJECTIONS:
BENEFITS OF KLOTIN 100 MG INJECTIONS:
In Treatment of Bleeding
Draining happens when blood clumps separate quickly. Klotin 100mg Injection diminishes draining by forestalling the quick breakdown of clusters. It assists with forestalling extreme loss of blood, quits dying, and improves the recuperating system. Draining can cause you to feel frail so it is fitting to take a decent eating regimen relying upon your condition and with a specialist's counsel.
MECHANISM OF ACTION OF KLOTIN 100 MG INJECTIONS:
Klotin 100mg Injection is an enemy of fibrinolytic. It works by forestalling the breakdown of blood clusters to control inordinate draining during periods, or after medical procedure.
Product Details:
Country of Origin | Made in India |
Product Details:
Packaging Size | Bottle |
Composition | Lidocaine (15% w/w) |
Manufacturer | Icpa Health Products Ltd |
Dose | 15% |
Brand | Icpa Health Products Ltd |
Treatment | Local anesthesia (Numb tissues in a specific area) |
Type Of Medicines | spray |
Prescription/Non prescription | Prescription |
Form | Syrup |
Gender | Unisex |
Introduction of Nummit Spray fresh mint :
Nummit Spray Fresh Mint is a nearby sedative used to numb specific region of the body briefly. It is utilized as a sedative oil to embed instruments in the human body for operations (e.g., catheters). It is additionally utilized for the treatment of side effects of difficult aggravation of the urethra and bladder.
The most widely recognized symptoms of this medication incorporate redness, rash, consuming, and tingling at the site of utilization. These are generally gentle and fleeting. Counsel your doctor assuming that any of the secondary effects continue or concern you.
Uses of Nummit Spray fresh mint :
• Nearby sedation (Numb tissues in a particular region)
Benefits of Nummit Spray fresh mint :
In Local sedation (Numb tissues in a particular region)
Nummit Spray Fresh Mint is a nearby sedative. It makes your skin numb. As a gel or cream, it tends to be utilized to ease torment, bothering, or tingling brought about by a wide assortment of conditions. It is for the most part exceptionally protected, works rapidly, and will lessen the uneasiness that may be brought about by an infusion, having a trickle (cannula) put into your skin or a little superficial or other surgery.
It is likewise utilized in techniques requiring the inclusion of a cylinder into your mouth, nose, rear-end (proctoscopy) or bladder (cystoscopy) can be awkward and, surprisingly, difficult. Lidocaine can be applied to the outer layer of the cylinder before it is embedded. This will both grease up the cylinder and give a sedative impact, making the methodology more agreeable.
Mechanism of action of Nummit Spray fresh mint :
Nummit Spray Fresh Mint is a neighborhood sedative. It deals with the skin by hindering agony signals from the nerves to cerebrum. This numbs the region and diminishes torment sensation.
Product Details:
Brand Name | Dextomid 200mcg Injection |
Manufacturer | Neon Laboratories Ltd |
Dose | 50mcg |
Packaging Type | VIAL |
Packaging Size | 1 ml |
Composition | Dexmedetomidine 50mcg |
Introduction of Dextomid 50mcg injection:
Dextomid 50mcg Injection is a doctor prescribed medication used to give sedation (a condition of quiet, sluggishness, or rest) for grown-up patients in concentrated care settings. It might likewise be utilized for alert sedation during demonstrative and surgeries.
Dextomid 50mcg Injection is given as an implantation (dribble) into a vein under the management of a medical services proficient. It is essential to illuminate your doctor in the event that you are experiencing any ailments like sluggish pulse, low circulatory strain, neurological turmoil, extreme liver issues, or have at any point fostered a serious fever after certain meds, particularly in the wake of taking sedation. Your doctor will screen the heart and respiratory state in the wake of giving this infusion.
Uses of Dextomid 50mcg injection:
• Narcotic
Bemnefits of Dextomid 50mcg injection:
In Sedative
Dextomid 50mcg Injection assists with quieting the movement of the nerves and initiates a covert government of rest called sedation. Consequently this medication goes about as a narcotic and is utilized in serious consideration units (ICUs) to give help to patients and to keep them calm. It can likewise be utilized to do a few demonstrative or minor surgeries. It is given as an infusion by a specialist or medical caretaker in an emergency clinic arrangement.
Mechanism of action of Dextomid 50mcg injection:
Dextomid 50mcg Injection works by tweaking the activity of specific substance couriers in the cerebrum that alleviates torment and actuates rest.
Ask For Price
Product Price:
Get Latest Price
Disposable mask, inflatable cushion, vanilla scented.
Colour code on ring for fixation harness (except sizes 1 and 2). Not sterile.
|
Face mask |
|||
Code |
Connection |
Corresponds to body size |
Size |
|
5557.15 |
15 (male) |
Neonatology |
1 |
|
5557.150 |
15 (female) |
Neonatology |
1 |
|
5557.25 |
15 (male) |
Child |
2 |
|
5557.250 |
15 (female) |
Child |
2 |
CAT.NO. | DESCRIPTION |
6517 | Y connector (Hemostasis Valves) screw type |
SIZES |
---|
Size | 8 | 10 | 12 | 14 | 16 | 20 | 24 | 28 | 32 | 36 |
Length (mm) | 230 | 230 | 230 | 230 | 230 | 390 | 390 | 390 | 390 | 390 |
Vygon Spike (green) Single use, sterile, needleless device intended for fluid withdrawal, powdered medicine reconstitution and injection.
It is recommended for the reconstitution of sterile medicines: the preparation of powdered or lyophilisate solutions, preparation of eye drops, etc, and for repeated withdrawals from the same vial using a syringe.
Specifications
Additional information
Spike
Code Filter porosity
µm Filtering area
cm² Flowrate
ml/min Priming volume
ml Utilization pressure (maximum)
bar
281.01 0.1 0.36 39 à 12 mbar 0.16 1
281.02 5 1.29 - 0.16 1
Product Details:
Country of Origin | Made in India |
Device for aspiration of mucus congesting the upper airways of the newborn or for suctioning tracheal / bronchial secretions (of newborns, children and adults) which will be analysed in laboratory.
Mucaid includes:
- 1 container (capacity 25 ml), with graduations from 0 to 25 ml for all models,
- 1 PVC extension tube 23 cm long with connector for finger-tip suction control, to connect the device to the suction source (mechanical / wall suction),
- 1 separate lid for safe sealing and transport of the aspirate,
- 1 label.
|
Suction tube |
Container |
|||
Code |
Length |
Ø ext. |
Volume |
Tubing to suction source - length |
|
|
542.06 |
26 |
6 |
25 |
24 |
542.08 |
33 |
8 |
25 |
24 |
|
542.10 |
33 |
10 |
25 |
24 |
Tube | ||||
---|---|---|---|---|
Code | Ext. Ø Fr |
Length cm |
Priming volume ml |
|
5590.106 | 6 | 20 | 0.2 |
Microflash is a peelable cannula introducer for 2Fr or 1Fr PICC or Midline catheters: 20G, 18mm long.
The lateral eye at the distal end of the needle and the transparent plastic cannula allow to quickly visualize blood flashback which indicates that the vessel has been successfully punctured. The cannula sheath also features a radiopaque stripe.
The ribbed wings prevent finger slippage while splitting the cannula.
|
Tube |
Needle |
|||||||
Code |
Ext. Ø |
Int. Ø |
Length |
For catheter |
Gauge |
Ext. Ø |
Int. Ø |
Length |
|
|
7370.19 |
1.1 |
0.7 |
18 |
2 |
21 |
0.7 |
0.5 |
31 |
Peripherally inserted central venous catheter in silicone (2Fr/24G) for medium and long-term access (parenteral nutrition, administration of medication) in premature babies and neonates.
Markings every centimetre and black mark at the distal end to ensure that the entire catheter has been withdrawn.
Removable connector Easy-lock type with integral PUR extension tube (length 10 cm).
Presented in a rigid blister pack containing:
Quantity box/case: 30/150
|
Catheter |
Introducer |
||||||||||
Code |
Int. Ø |
Ext. Ø |
Length |
Prim. vol. |
Flow rate (Pressure 1 bar) |
Flow rate by gravity |
Ø |
Type |
Length |
Ext. Ø |
G |
|
2184.00 |
0.3 |
0.6 |
30 |
0.12 |
3.0 |
- |
2 |
Winged needle |
27 |
1.0 |
19 |
|
2184.005 |
0.3 |
0.6 |
50 |
0.16 |
2.0 |
- |
2 |
Winged needle |
27 |
1.0 |
19 |
|
2184.015 |
0.3 |
0.6 |
15 |
0.10 |
4.0 |
- |
2 |
Winged needle |
27 |
1.0 |
19 |
|
2184.030 |
0.3 |
0.6 |
30 |
0.12 |
3.0 |
0.6 |
2 |
Microflash |
18 |
1.1 |
20 |
|
2184.152 |
0.3 |
0.6 |
15 |
0.10 |
4.0 |
0.7 |
2 |
Microflash |
18 |
1.1 |
20 |
The paediatric endotracheal tubes without cuff (code 5520.xx) consist of:
|
Secondary lumen |
Tube |
||||
Code |
Flow rate |
Ø |
Int. Ø |
Ext. Ø |
Length |
|
5520.20 |
2.15 |
0.40 |
2.0 |
3.4 |
165 |
|
5520.25 |
3.35 |
0.55 |
2.5 |
4.1 |
165 |
|
5520.30 |
5.00 |
0.65 |
3.0 |
4.6 |
165 |
|
5520.35 |
15.0 |
0.80 |
3.5 |
5.2 |
165 |
|
5520.40 |
35.0 |
0.95 |
4.0 |
5.7 |
230 |
|
5520.45 |
80.0 |
1.15 |
4.5 |
6.2 |
230 |
Length (mm) |
|||||
Diameter |
06 |
09 |
10 |
12 |
15 |
1.00 |
6910006 |
6910009 |
6910010 |
6910012 |
6910015 |
1.25 |
6912506 |
6912509 |
6912510 |
6912512 |
6912515 |
1.50 |
6915006 |
6915009 |
6915010 |
6915012 |
6915015 |
1.75 |
6917506 |
6917509 |
6917510 |
6917512 |
6917515 |
2.00 |
6920006 |
6920009 |
6920010 |
6920012 |
6920015 |
2.25 |
6922506 |
6922509 |
6922510 |
6922512 |
6922515 |
2.50 |
6925006 |
6925009 |
6925010 |
6925012 |
6925015 |
2.75 |
6927506 |
6927509 |
6927510 |
6927512 |
6927515 |
3.00 |
6930006 |
6930009 |
6930010 |
6930012 |
6930015 |
3.25 |
6932506 |
6932509 |
6932510 |
6932512 |
6932515 |
3.50 |
6935006 |
6935009 |
6935010 |
6935012 |
6935015 |
3.75 |
6937506 |
6937509 |
6937510 |
6937512 |
6937515 |
4.00 |
6940006 |
6940009 |
6940010 |
6940012 |
6940015 |
Octopus is a polyurethane multi-lumen extension tube for I.V. catheters, transparent and with low priming volume.
To identify the different infusion lines, each tube has a clamp of different colour.
Octopus 2 (code 841.234) is a 2-lumen extension tube with a clamp (Roberts type) on each lumen. Length: 3cm / 3cm.
This product is recommended for neonatal and paediatric units which need to run two IV infusions simultaneously.Specifications
Additional information
Extension tube
Code Int. Ø
mm Ext. Ø
mm Length
cm Priming volume on each lumen
ml Total priming volume
ml
841.234 1.50 (x2) 2.50 (x2) 3 (x2) 0.25 (x2) 0.40
Code 807.01 and 807.02: 0.22µm air eliminating filter, with PVC extension tube, for filtration of bacteria, endotoxins and particulate matter (latex, glass etc.). Duration of use: up to 96 hours - Supplied with day change labels.
N.B.: Filter is not compatible with lipids and blood.
Code 807.102: 1.2µm air eliminating filter for lipidic solutions with PVC extension tube with clamp. Duration of use: up to 24 hours - Supplied with day change labels.
N.B.: Filter is not compatible with blood.
Code 807.01: with injection site. Total length 35cm. Dead volume: 4.4ml.
Code 807.02: without injection site. Total length 24cm. Dead volume: 3.6ml.
Code 807.102: without injection site. Total length 30cm. Dead volume: 3.6ml.
Low protein binding filter.
Specifications
Additional information
Extension tube
Code Length
cm Prim. vol.
ml Flow rate
ml/min
807.01 35 |
4.4 |
>21 >19 |
807.02 24 |
3.6 |
|
807.102 24 |
3.6 |
>30 |
CAT.NO. | DESCRIPTION |
6517PP | Y connector (Hemostasis Valves) Push pull type |
Female Luer-lock to female Luer-lock connector in polycarbonate. Additional information
Contains Latex: No
Contains DEHP: No
Contains biogical or animal-based product: No
Non-pyrogenic: Yes
Disposable, sterile laryngoscope blade "Mac Intosh" or "Miller" type, with fibre optic light source. Supplied in a protective cover to reduce the risk of cross-contamination.
N.B. For use only with Safescope laryngoscope handlescodes 692.01/692.02/692.03.
20/180
|
Laryngoscope blade |
||
Code |
Type of blade |
Indication |
|
691.01 |
Mac Intosh n°1 |
Pédiatrie |
|
691.10 |
Miller n°0 |
Néonatalogie |
|
691.11 |
Miller n°1 |
Pédiatrie |
|
691.20 |
Miller n°00 |
Néonatalogie |
4-way stopcock for exchange transfusion with injection membrane for intermittent drug injections. Contains Latex: No
Contains DEHP: No
Contains biogical or animal-based product: No
Non-pyrogenic: Yes
CAT.NO. | SIZE | DESCRIPTION |
RPS 16G | 16G | PUNCTURE SHEATH 16G |
RPS 18G | 18G | PUNCTURE SHEATH 18G |
RPS 20G | 20G | PUNCTURE SHEATH 20G |
EFFECTIVE LENGTH | TOTAL LENGTH |
119cm | 122cm |
SIZES |
---|
FG | 10 | 12 | 14 | 16 | 18 | 20 |
Colour Code | Black | White | Green | Orange | Red | Yellow |
Extension tube
Code Int. Ø
mm Ext. Ø
mm Prim. vol.
ml Length
cm Pressure tested at
bar Flow rate
ml/min
1155.60 1.0 2.0 1.1 100 40 16
1155.65 1.0 2.0 1.5 150 40 12
1155.70 1.0 2.0 2.0 200 40 7.5
1155.80 1.0 2.0 2.8 300 40 5.6
1155.90 1.0 2.0 3.7 400 40 4.8
1159.60 1.5 2.5 1.9 100 40 40
1159.65 1.5 2.5 2.7 150 40 28
1159.70 1.5 2.5 3.6 200 40 25
1159.80 1.5 2.5 5.2 300 40 19
1159.90 1.5 2.5 6.9 400 40 15
Product Details:
Country of Origin | Made in India |
SIZES |
Size | 10FG , 12FG , 14FG , 16FG & 18FG |
Length | 20 x 60cm |
SIZES |
Chamber Capacity | 25ml |
Catheter Size | 10FG |
EFFECTIVE LENGTH | TOTAL LENGTH |
119cm | 122cm |
SIZES |
---|
FG | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 |
Colour Code | Green | Blue | Black | White | Green | Orange | Red | Yellow |
Low coefficient of friction minimises tissue damage
• Silicon elastomer provides inert coating avoiding adverse effects of PVC
• Longer indwell times leads to cost savings and reduced patient trauma while intubation and removal
EFFECTIVE LENGTH | TOTAL LENGTH |
119cm | 122cm |
SIZES |
---|
FG | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 |
Colour Code | Green | Blue | Black | White | Green | Orange | Red | Yellow |
SIZES – CUFFED |
---|
5.0 mm, 5.5 mm, 6.0 mm, 6.5 mm, 7.0 mm, 7.5 mm,8.0 mm, 8.5 mm, 9.0 mm, 9.5 mm |
SIZES – PLAIN |
---|
3.0 mm, 3.5 mm, 4.0 mm, 4.5 mm, 5.0 mm, 5.5 mm,6.0 mm, 6.5 mm, 7.0 mm, 7.5 mm, 8.0 mm, 8.5 mm |
SIZES |
Length | 110cm | 150cm | 200cm |
Prime Volume | 0.9ml | 1.40ml | 1.80ml |
EFFECTIVE LENGTH | TOTAL LENGTH |
37cm | 40cm |
SIZES |
---|
FG | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 |
Colour Code | White | Green | Orange | Red | Yellow | Voilet | Blue | Pink |
SIZES |
---|
Size | 12 | 14 | 16 | 20 | 24 | 28 | 32 | 36 |
Length (mm) | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 |
The paediatric endotracheal tubes without cuff (code 5516.xx) consist of:
Ext. Ø |
Length |
Tube |
||||
3.4 |
165 |
Ø |
Int. Ø |
|
|
|
4.1 |
165 |
2.15 |
0.40 |
2.0 |
|
|
4.6 |
165 |
3.35 |
0.55 |
2.5 |
|
|
5.2 |
165 |
5.00 |
0.65 |
3.0 |
|
|
5.7 |
230 |
15.0 |
0.80 |
3.5 |
|
|
6.2 |
230 |
35.0 |
0.95 |
4.0 |
|
|
5516.45 |
80.0 |
1.15 |
4.5 |
|
|
Used for short term bladder catheterization s Made from non-toxic, non-irritant, medical grade PVC s Radio opaque line provided through out the catheter for X-ray visualization s Distal end with lateral eyes and proximal end funnel connector, for maximum drainage and easy connection to the urine bag
VERSION |
EFFECTIVE LENGTH |
TOTAL LENGTH |
Male |
370mm |
400mm |
Female |
170mm |
200mm |
SIZES |
||||||||
FG |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
Colour Code |
Green |
Blue |
Black |
White |
Green |
Orange |
Red |
Yellow |
Triple-layer extension tube (PVC/EVA/PE) with side outlet for I.V. catheter.This extension tube has a male Luer-lock connector at the distal end and a "Y" connector at the proximal end with female Luer-lock ports.The side outlet is fitted with an injection cap for drug injections with a needle.Diameter of the extension tube : 2.5 x 4.0 mm.
|
Extension tube |
||||
Code |
Int. Ø |
Ext. Ø |
Prim. vol. |
Length |
|
|
140.00 |
2.5 |
4.0 |
1.80 |
25 |
|
140.80 |
2.5 |
4.0 |
4.50 |
80 |
Code |
Int. Ø |
Ext. Ø |
Gauge |
Length |
Flow rate (Pressure 1 bar) |
Prim. vol. |
Flow rate by gravity |
Ø |
Length |
G |
Type |
Ext. Ø |
- |
|
1252.030 |
0.3 |
0.6 |
24 |
30 |
5.0 |
0.12 |
- |
2 |
18 |
20 |
Microflash |
1.1 |
Yes |
|
1252.15 |
0.3 |
0.6 |
24 |
15 |
9.0 |
0.06 |
- |
2 |
23 |
20 |
Splitting needle |
0.95 |
No |
|
1252.150 |
0.3 |
0.6 |
24 |
15 |
9.0 |
0.06 |
- |
2 |
18 |
20 |
Microflash |
1.1 |
No |
|
1252.30 |
0.3 |
0.6 |
24 |
30 |
5.0 |
0.12 |
- |
2 |
23 |
20 |
Splitting needle |
0.95 |
No |
|
1252.35 |
0.3 |
0.6 |
24 |
30 |
5.0 |
0.12 |
- |
2 |
18 |
20 |
Microflash |
1.1 |
No |
|
1253.15 |
0.5 |
1.0 |
20 |
15 |
- |
0.09 |
5.0 |
3 |
30 |
17 |
Splitting needle |
1.5 |
No |
|
1253.30 |
0.5 |
1.0 |
20 |
30 |
20.0 |
0.16 |
- |
3 |
30 |
17 |
Splitting needle |
1.5 |
No |
|
1254.30 |
0.8 |
1.3 |
18 |
30 |
90.0 |
0.42 |
- |
4 |
30 |
16 |
Splitting needle |
1.6 |
No |
|
1352.152 |
0.3 |
0.6 |
24 |
15 |
9.0 |
0.06 |
- |
2 |
21 |
20 |
Microflash |
1.0 |
No |
Code |
- |
Int. Ø |
Ext. Ø |
Length |
Total priming volume |
Priming vol. lumen 1 |
Priming vol. lumen 2 |
Flow rate lumen 2 |
Flow rate lumen 1 |
Pressure tested at |
Length |
Priming volume |
Flow rate |
Maximum pressure in use |
|
807.204 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
0.43 |
5.80 |
2 |
|
807.205 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
24 |
0.59 |
2.5 |
2 |
|
836.201 |
0.22 |
1.5 |
2.5 |
2 - 15 |
0.90 |
0.24 |
0.84 |
2.5 |
75 |
2 |
- |
- |
- |
- |
|
836.202 |
0.22 |
1.5 |
2.5 |
20.5 (x2) |
1.1 |
0.95 |
0.95 |
2.5 |
2.5 |
2 |
- |
- |
- |
- |
|
836.204 |
0.22 |
1.5 |
2.5 |
11 |
0.64 |
- |
- |
- |
4.5 |
2 |
- |
- |
- |
- |
|
836.205 |
0.22 |
1.5 |
2.5 |
2 - 20.5 (x2) |
1.3 |
0.98 (x2) |
0.26 |
75 |
2.5 |
2 |
- |
- |
- |
- |
|
836.210 |
0.22 |
1.5 (x3) |
2.5 (x3) |
2 - 20.5 (x2) |
1.4 |
1.0 (x2) |
0.26 |
75 |
2.5 (x2) |
2 |
- |
- |
- |
- |
Vystar female / male: ramp of two 3-way stopcocks
Vystar ramp of stopcocks is an add-on device for intravenous catheters comprising:
a body molded in a lipid-resistant raw material (polycarbonate) and transparent to detect air bubbles to facilitate the priming of the device.
stopcocks in polyoxymethylene (POM), each stopcock having a different colour.
Pressure tested to 2 bars during 15 minutes meeting the requirements of the ISO norm 8536-10.
The extension tube supplied with Vystar ramps (except code 5827.92: without extension tube) is made of 3 layers. The outer layer is in PVC, the inner layer is in Polyethylene without additives, material presenting a high chemical inertness and the intermediate layer is Ethyl Vinyl Acetate, material linking the inner and the outer layers.
This structure allows to minimize interations with drugs and leaching of plasticizers from the PVC into the administered solutions.
Some models of Vystar ramps are supplied with Bionector a multi-purpose, closed, needle-free connector allowing blood sampling, intermittent injections or continuous infusions of fluids or drugs.
Ramp only: code 5827.92
Ramp only + 3 Bionector: code 5827.922
Ramp with extension tube length 50 cm: code 5827.02
Ramp with extension tube length 100 cm: code 5827.12
Ramp with extension tube length 150 cm: code 5827.22
Ramp with extension tube length 150 cm + ramp holder: code 5827.221
Ramp with extension tube length 150 cm + 3 Bionector: code 5827.222
Ramp with extension tube length 150 cm + 3 Bionector + ramp holder: code 5827.223
Ramp with extension tube length 200 cm + 3 Bionector + ramp holder: code 5827.523
Shelf life 5 years except ramps with Bionector: 3 years.
Ramp of stopcocks
Code Priming volume
I.V. extension tube in flexible, transparent polyurethane tubing with Bionector TKO and mini Roberts clamp.
Octopus with Bionector TKO is a multi-purpose catheter accessory, a single lumen I.V. extension tube with needleless connector, enabling intermittent injections or continuous infusions of fluids or medications and blood sampling.
Octopus with Bionector TKO is a needleless catheter patency device that has been specifically designed to reduce thrombotic catheter occlusions and works by controlling the bi-directional flow of fluid, infusate and catheter tip blood reflux.
Octopus with Bionector TKO has a very easily disinfectable membrane (disinfection must be carried out before and after use) which closes automatically when the infusion line or the syringe is disconnected.
The proximal end of Octopus with Bionector TKO is a female Luer-Lock fitting and will accept any device featuring a male Luer or male Luer-Lock fitting (syringe, infusion set ...).
Octopus with Bionector TKO features a male connector with mobile locking device to connect it to all devices featuring a female Luer-Lock hub (IV catheter…).
Octopus with Bionector TKO has the following advantages:
- Prevents occlusion risks from
. syringe and infusion set disconnection
. syringe plunger rebound
. IV bag running dry
. venous pressure changes (cough…)
- Eliminates the risk of access-associated needle-stick injury
- Reduces the risk of cannula movement in the vein causing mechanical vein irritation
- Provides closed system (avoiding blood reflux) when accessing the catheter
- PUR material (no PVC, DEHP-free), no leaching of plasticizers.
Octopus with Bionector TKO is lipid-resistant.
Priming volume : 0.75 ml.
Maximum infusion/injection pressure is 240 psi (16.5 bar).
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and oxygenated water.
Specifications
Additional information
Brochure
Extension tube |
|||||||
Code |
Length |
||||||
cm |
Int. Ø |
||||||
mm |
Ext. Ø |
||||||
mm |
Prim. vol. |
||||||
ml |
Flow rate |
||||||
ml/min |
|
||||||
5222.838 |
27 |
1.50 |
2.50 |
0.75 |
40 |
||
Product Details:
Brand | CIRCUMCISION DEVICE |
Material | Stainless Steel |
Color | White |
Country of Origin | Made in India |
Benefits of Laser Circumcision
Don't Fear Circumcision
CAT.NO. | SIZE | DESCRIPTION |
661234567 | 12ML | CONTROL SYRINGE WITH MALE ROTATOR |
CAT.NO. | DESCRIPTION |
646190 | ASPIRATION CATHETER 6F |
647190 | ASPIRATION CATHETER 7F |
CAT.NO. | DESCRIPTION |
TR1 | RADIAL COMPRESSION BAND - SCREW TYPE |
TR2 | RADIAL COMPRESSION BAND - AIR TYPE |
CAT.NO. | DESCRIPTION |
6458 | 9F Y-connector with torque device and insertion tool |
SIZES |
Total Length – 35cm |
FG | 4 | 5 | 6 | 8 | 10 |
Colour Code | White | Grey | Green | Blue | Black |
Product Details:
Country of Origin | Made in India |
Needle-free drug aspiration; for multiple vial access.
50/600
|
Cap |
|
Code |
Ø |
|
|
821.21 |
14 |
821.22 |
20 |
|
856.01 |
- |
|
856.11 |
- |
CAT.NO. | DESCRIPTION |
6458PP | ANGIOKIT PUSH PULL |
Premistar is a 1Fr peripherally inserted central venous catheter. It is used for short and medium-term infusion of total parenteral nutrition or intravenous medications, up to 29 days, in low weight premature babies.
Premistar is made of radiopaque polyurethane incorporated with the Star technology. The Star technology is a combination of two antiinfectives: Rifampicin and Miconazole, delivering a local antimicrobial action at the catheter’s surfaces.
Premistar is presented in a rigid tray containing:
Premistar codes 6261.206 and 6261.306 are supplied without introducer. The practitioner can thus choose the introducer that fits him best: standard short IV cannula, splitting needle, peelable cannula...
Some models of Premistar are supplied with a stylet (see table of technical characteristics). The stylet is supplied with a Y connector. A syringe filled with saline solution can be connected to the lateral port of the Y connector to prime / flush the catheter and to lubricate the stylet.
|
Catheter |
Introducer |
Stylet |
||||||||
Code |
Ø |
Length |
Ext. Ø |
Flow rate (Pressure 1 bar) |
Prim. vol. |
Type |
G |
Ext. Ø |
Length |
- |
|
|
6261.20 |
1 |
20 |
0.35 |
0.7 |
0.09 |
Splitting needle |
24 |
0.7 |
19 |
No |
6261.203 |
1 |
20 |
0.35 |
0.7 |
0.09 |
Splitting needle |
24 |
0.7 |
19 |
Yes |
|
6261.206 |
1 |
20 |
0.35 |
0.7 |
0.09 |
- |
- |
- |
- |
Yes |
|
6261.306 |
1 |
30 |
0.35 |
0.6 |
0.11 |
- |
- |
- |
- |
Yes |
Umbilical polyurethane catheter, totally radiopaque with Expert technology, containing the AgION™ antimicrobial agent made of silver ions integrated within the wall of the catheter, used for short term venous catheterisation.
The Expert catheters release silver ions on their internal and external surfaces, so the catheter offers both intraluminal and extraluminal protective action.
Because the silver ions are sensitive to light (photoreactive), the catheter is supplied within a green protective tubing.
Numerical graduations every centimetre from 4 to 25 cm from the distal tip.
This catheter is supplied with a 3-way stopcock (Vyclic Color) with identification plugs: blue (venous access) and red (arterial access).
Sizes available
2.5Fr: Length 30 cm (8270.230)
3.5Fr, 4Fr, 5Fr and 8Fr: Length 40 cm (8270.340, .440, .540 and .840)
|
Catheter |
|||||||
Code |
Ø |
Length |
Lumen |
Int. Ø |
Ext. Ø |
Flow rate |
Prim. vol. |
|
|
8270.230 |
2.5 |
30 |
- |
0.5 |
0.8 |
2.2 |
0.1 |
8270.340 |
3.5 |
40 |
- |
0.8 |
1.2 |
12 |
0.3 |
|
8270.440 |
4 |
40 |
- |
0.8 |
1.5 |
12 |
0.3 |
|
8270.540 |
5 |
40 |
- |
1.0 |
1.7 |
27 |
0.4 |
|
8270.840 |
8 |
40 |
- |
1.5 |
2.5 |
109 |
0.8 |
|
8272.420 |
4 |
20 |
2 |
2 x 0,5 |
1.5 |
2 x 13,8 |
2 x 0,3 |
|
8272.440 |
4 |
40 |
2 |
2 x 0,5 |
1.5 |
2 x 8,1 |
2 x 0,4 |
|
8272.540 |
5 |
40 |
2 |
2 x 0,7 |
1.7 |
2 x 6,4 |
2 x 0,3 |
Protect-a-set (code 836.02) and Octopus 2 (other codes) are polyurethane, transparent, supple with low dead space double-lumen extension tubes for IV catheters (peripheral or central venous) fitted with one or 2 Bionector.
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
They allow to connect to the catheter several independant IV lines.
Code 836.02 is a double lumen extension tube with 1 non-return valve, 1 hub with Bionector and 1 clamp (white).
Length of tubes: 6 cm / 10 cm.
Code 841.232 is a double lumen extension tube with 2 non-return valves, 2 Bionector and 2 clamps (green).
Length of tubes: 3 cm / 3 cm.
Code 841.264 is a double lumen extension tube with 2 Bionector and 2 clamps (green and orange).
Length of tubes: 10 cm / 10 cm.
Code 842.209 is a double lumen extension tube with 1 non-return valve, 2 Bionector and 2 clamps (green and orange). The end without non-return valve allows the sampling blood.
Length of tubes: 6 cm / 6 cm
Used for peripheral cannula care, Octopus 2 has the following advantages:
Eliminates the risk of access-associated needle-stick injury
Reduces the risk of cannula movement in the vein causing mechanical vein irritation
Negates the need to use the cannula injection port (non disinfectable), Bionector is disinfectable
Eliminates the need to use a 3-way tap to run simultaneous compatible solutions
Provides closed system (avoiding blood reflux) when accessing the catheter
PUR material (no PVC, DEHP-free - no release of softeners)
Non-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and hydrogen peroxide.
For more information about Bionector, please refer to technical file code 896.
Octopus with Bionector are also available with 1 lumen (code 5222.014), 3 lumen (codes 841.364-842.311/312), 4 lumen (code 842.414) and 5 lumen (code 842.514).
Biovystar / Vystar ramp of stopcocks is an add-on device for intravenous catheters comprising:
a body molded in a lipid-resistant raw material (polycarbonate) and transparent to detect air bubbles to facilitate the priming of the device.
stopcocks in polyoxymethylene (POM), each stopcock having a different colour.
Pressure tested to 2 bars during 15 minutes meeting the requirements of the ISO norm 8536-10.
The extension tube supplied with Biovystar / Vystar ramps (except code 5828.92: without extension tube) is made of 3 layers. The outer layer is in PVC, the inner layer is in Polyethylene without additives, material presenting a high chemical inertness and the intermediate layer is Ethyl Vinyl Acetate, material linking the inner and the outer layers.
This structure allows to minimize interations with drugs and leaching of plasticizers from the PVC into the administered solutions.
Some models of Biovystar / Vystar ramps are supplied with Bionector or Vadsite which are multi-purpose, closed, needle-free connectors allowing blood sampling, intermittent injections or continuous infusions of fluids or drugs.
Just the ramp: code 5828.92
Ramp with extension line length 50 cm: code 5828.02
Ramp with extension line length 100 cm: code 5828.12
Ramp with extension line length 150 cm: code 5828.22
Ramp with extension line length 50 cm + ramp holder: code 5828.021
Ramp with extension line length 150 cm + ramp holder: code 5828.221
Ramp with extension line length 50 cm + 3 Bionector + ramp holder: code 5828.023
Ramp with extension line length 150 cm + 3 Bionector + ramp holder: code 5828.223
Ramp with extension tube length 50 cm + 3 Vadsite + ramp holder: code 5828.025
Ramp with extension tube length 100 cm + 3 Vadsite + ramp holder: code 5828.125
Ramp with extension tube length 150 cm + 3 Vadsite + ramp holder: code 5828.225
Ramp with extension tube length 200 cm + 3 Vadsite + ramp holder: code 5828.525
Shelf life 5 years except ramps with Bionector: 3 years.
Code 37.09.14: Neo-HeLP SMALL - For newborns < 1 kg - Dimensions: 30 x 38 cm
Code 37.09.15: Neo-HeLP MEDIUM - For newborns between 1 kg and 2.5 kg - Dimensions: 38 x 44 cm
Code 37.09.16: Neo-HeLP LARGE - For newborns > 2.5 kg - Dimensions: 38 x 50 cm
Neo-HeLP is a polyethylene occlusive suit to prevent hypothermia of newborns.
This is a sterile suit in which the baby is placed immediately after birth without drying (before being admitted to the ICU).
Heat loss due to environmental factors (evaporation, convection, conduction and radiation) is limited.
Neo-HeLP consists of:
Neo-HELP is an ingenious pouch completely transparent, to monitor the color of the newborn's skin and breath movements, and easy to use with direct access to the baby through the open / closed central opening.
Neo-HELP is suitable for all situations (delivery room, place of resuscitation, emergency, operating room, transport ...) and all users.
It is recommended not to use Neo-HeLP for more than 24 hours. In general, Neo-HeLP is used for a maximum of two hours after birth or in accordance with established clinical protocol.
CAT.NO. DESCRIPTION
33060MF 60 cm injector line with male / Female connectors
33120MF 120 cm injector line with male / Female connectors
33150MF 150 cm injector line with male / Female connectors
33200MF 200 cm injector line with male / Female connectors
Siliconized stainless steel needle with double wings for insertion of PICCs (Peripherally Inserted Central Catheters) such as Premicath, Nutriline, Nutriline Twinflo, Lifecath PICC, Lifecath Midline...
4 codes are available:
|
For catheter |
Needle |
|||
Code |
of ext.Ø |
Ext. Ø |
Length |
Gauge |
|
7366.510 |
1 |
0.70 |
19 |
24 |
|
7366.710 |
2 |
0.90 |
25 |
20 |
|
7366.810 |
4 |
1.60 |
30 |
16 |
|
7366.910 |
3 |
1.40 |
30 |
17 |
Insertion kit for central venous catheter 1 Fr or 2 Fr with the modified Seldinger technique.
The kit contains the following components :
The kit allows introducing central venous catheters in premature babies with very small veins that are generally difficult to catheterize.
The nitinol guidewire is kink-resistant and the soft tips avoid venous trauma.
The peelable sheath allows easy dilation of the puncture site and introduction of a 2 Fr catheter or less.
Quantity box: 10
|
Needle |
Split cannula |
Guidewire |
|||
Code |
Gauge |
Length |
Ø |
Length |
Length |
|
|
1147.02 |
24 |
19 |
2 |
18 |
20 |
Recommended for critical care patients; neonates, paediatrics, and adults. Bionector TKO has the advantage of low dead space, neutral fluid displacement and TKO valve to prevent accidental catheter occlusion, particularly useful with gravity infusion and physiological changes (coughing, vomiting, crying, ...).
Applications include:
- Blood sampling, intermittent injections, continuous infusions of fluids or drugs.
- Needleless device, specifically designed to reduce catheter occlusion, by controlling the bi-directional flow of fluid, infusate and catheter tip blood reflux.
Bionector TKO features an internal valve that opens on injection and infusion. If the pressure is too low (IV bag running dry), the valve closes protecting the patient by preventing blood reflux. The internal valve opens under a withdrawal pressure of 7.0psi. If Read More »
Specifications
Additional information
Brochure
Bionector
Code Flow rate
ml/min Priming volume
ml
838.01 E 55 0.1
To overcome the problem of backtracking when two solutions of different densities are used. The higher density solution should always be attached to the lateral port.
25/600
4.9/5
Reviewed by 134 Users
Most Relevant Reviews