SIZES |
Size in FG | 14 | 16 | 18 | 20 | 22 | 24 |
Colour Code | Orange | Grey | Green | Pink | Blue | Yellow |
Length | 45mm | 45mm | 45mm | 32mm | 25mm | 19mm |
The triple lumen umbilical catheter is used for short term catheterization through the umbilical vein when a multiple access is needed.
It is used for TPN administration, & injection of drugs, particularly administration of drugs with incompatible features or when one drug needs to be infused continually at a slow rate (ex. inotropes).
This device allows to reduce the number of peripheral routes needed and so the number of insertions, optimising the infant's comfort.
The secondary functions of the catheter are blood sampling, transfusion and measurement of central venous pressure.
The catheter is made of radiopaque polyurethane (PUR) with markings every centimer. It is equipped with a soft green distal tip to reduce the trauma to the vessel. It has three extension lines with three color-coded hubs to better identify each lumen.
|
Catheter |
Distal lumen |
Medial lumen |
Proximal lumen |
|||||
Code |
Ø |
Length |
Flow rate |
Prim. vol. |
Flow rate |
Prim. vol. |
Flow rate |
Prim. vol. |
|
|
V02127315 |
4.5 |
20 |
7.4 |
0.2 |
2 |
0.17 |
2.1 |
0.17 |
The nasopharyngeal suction catheter is used for oral/nasal/pharyngeal suction to eliminate all liquids (secretions, blood, etc.) clogging this space.
This suction catheter is composed of:
These suction catheters are available in 3 external diameters: 6Fr (codes 522.06 / 80522.06B), 8Fr (codes 522.08 / 80522.08B) and 10Fr (codes 522.10 / 80522.10B).
|
Tube |
||
Code |
Length |
Ext. Ø |
|
|
522.06 |
15 |
6 |
522.08 |
15 |
8 |
|
522.10 |
15 |
10 |
|
80522.06B |
15 |
6 |
|
80522.08B |
15 |
8 |
|
80522.10B |
15 |
10 |
Plain endotracheal tube (without cuff) made of:
10 sizes are available: from 2.0mm internal diameter to 6.5mm.
|
Distal mark |
Tube |
|||
Code |
Length |
Int. Ø |
Ext. Ø |
Length |
|
|
516.20 |
15 |
2.0 |
3.4 |
165 |
516.25 |
17.5 |
2.5 |
4.1 |
165 |
|
516.30 |
25 |
3.0 |
4.6 |
165 |
|
516.35 |
25 |
3.5 |
5.2 |
165 |
|
516.40 |
25 |
4.0 |
5.7 |
230 |
|
516.45 |
25 |
4.5 |
6.2 |
230 |
|
516.50 |
25 |
5.0 |
7.0 |
230 |
|
516.55 |
25 |
5.5 |
8.0 |
270 |
|
516.60 |
25 |
6.0 |
8.5 |
270 |
|
516.65 |
25 |
6.5 |
9.0 |
270 |
Silicone nasal tube for neonatal ventilation.
Length of tube: 9 cm.
|
Tube |
||||
Code |
Int. Ø |
Ext. Ø |
Diameter |
Length |
|
2595.15 |
1.5 |
2.7 |
8 |
9 |
|
2595.20 |
2.0 |
3.4 |
10 |
9 |
|
2595.25 |
2.5 |
4.0 |
12 |
9 |
|
2595.30 |
3.0 |
5.0 |
15 |
9 |
|
2596.15 |
1.5 |
2.7 |
8 |
6 |
|
2596.20 |
2.0 |
3.4 |
10 |
6 |
|
2596.25 |
2.5 |
4.0 |
12 |
6 |
|
2596.30 |
3.0 |
5.0 |
15 |
7 |
Cafneon 40mg Injection is a prescription medicine used in the treatment of apnea (a disorder in which breathing repeatedly stops and starts) of prematurity. It facilitates normal breathing and reduces interrupted breathing in premature newborns.
Cafneon 40mg Injection is given under the supervision of healthcare professionals. Remember, if you are breastfeeding while your infant is treated with this medicine, then do not drink coffee or take any other high caffeine product as this passes into breast milk.
Some common side effects of this medicine include mild delirium, insomnia, frequent urge to urinate, dehydration, tachycardia, and fever. Consult your doctor if these do not go away or persist for a longer duration. They may be able to suggest ways to prevent or reduce the side effects
Bore: 2.1 mm
50/900Additional information
Contains Latex: No
Contains DEHP: No
Contains biogical or animal-based product: No
Non-pyrogenic: Yes
atheter in radiopaque and transparent PVC, can be used for umbilical venous catheterisation (parenteral nutrition, drug administration, exchange transfusion, blood sampling...) or for umbilical arterial catheterisation (blood gas analysis, blood pressure measurement...)
Distance markings every centimetre from 4 to 25 cm.
Open and smoothed distal tip to reduce vascular trauma.
Available in 6 catheter diameters: 3.5* - 4 - 5 - 6 - 7 and 8 Fr
Length: 37 cm
* to be ordered under code 270.03
Quantity box/case: 15/225
| Catheter | |||||
Code | Length | Ø | Flow rate | Prim. vol. | Ext. Ø | |
| 270.03 | 37 | 3.5 | 6 | 0.19 | 1.16 |
270.04 | 37 | 4 | 16 | 0.27 | 1.50 | |
270.05 | 37 | 5 | 31 | 0.38 | 1.70 | |
270.06 | 37 | 6 | 52 | 0.51 | 2.00 | |
270.07 | 37 | 7 | 80 | 0.59 | 2.30 | |
270.08 | 37 | 8 | 106 | 0.75 | 2.50 |
Octopus 3 with Bionector is a polyurethane, transparent, supple multi-lumen extension tube for IV catheters (peripheral or central venous).
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
It allows to connect to the catheter several independant IV lines.
Code 841.364 is a triple lumen extension tube with 3 Bionector and 3 clamps (green, orange and white).
Length of tubes: 10 cm / 10 cm / 10 cm
Code 842.312 is a triple lumen extension tube with 3 non-return valves, 3 Bionector and 3 clamps (white, green, orange).
Length of tubes: 6 cm / 6 cm / 6 cm
Code 842.311 is a triple lumen extension tube with 2 non-return valves, 3 Bionector and 3 clamps (white, green, orange). The end without non-return valve allows the blood sampling.
Length of tubes: 6 cm / 6 cm / 6 cm
Used for central venous catheter care, Octopus 3 has the following advantages:
Provides a closed and disinfectable system with needle-free access
Eliminates the need to use a 3-way tap to run 2 or more simultaneous compatible solutions
Eliminates the risk of blood spillage
Eliminates the risk of air embolism
PUR material (no PVC, no DEHP - no release of softeners)
Non-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and hydrogen peroxide.
For more information about Bionector, please refer to the technical datasheet code 896.
Octopus with Bionector are also available with 1 lumen (code 5222.014), 2 lumen (codes 841.232/24/264/266E - 842.209), 4 lumen (code 842.414) and 5 lumen (code 842.514).
Code 807.504: Lipid-Filter
Neonatal/Paediatric 1.2 micrometer filter for lipid administration
24-hour air-eliminating filter, filtration of TPN solutions and retention of air, bacterial contaminants, and particulate matter.
Priming volume: 0.8ml, Flow rate: 90ml/min.
Code 807.506: Lipid-Filter
Neonatal/Paediatric 1.2 micrometer filter with extension line, for lipid administration
Triple-layer extension tube (PVC/EVA/PE) colour coded blue with a 24-hour air-eliminating filter, filtration of TPN solutions and retention of air, bacterial contaminants, and particulate matter.
Priming volume: 2.3ml, Flow rate: 7ml/min, Length of extension tube: 150cm.
Another lipidic filter is available under the code 836.207:
Code 836.207: Ready-set
Polyurethane extension tube with 2 access ports fitted with clamps, non-return valves and a 1.2 micrometer lipid, bacterial, particulate and air filter, 24 hours for lipidic solutions. Note: This air-eliminating filter is not suitable for blood or blood products.
2 identical lines: Priming volume: 1.3ml (x2) – Flow rate: 59ml/min (x2)
Length: 25cm – Total priming volume: 1.6ml
| Filter | Extension tube | Extension tube and/or filter |
| |||||||||||
Code | - | Int. Ø | Ext. Ø | Length | Total priming volume | Flow rate lumen 1 | Pressure tested at | Priming vol. lumen 1 | Priming vol. lumen 2 | Flow rate lumen 2 | Length | Priming volume | Flow rate | Maximum pressure in use | |
| 807.504 | - | - | - | - | - | - | - | - | - | - | - | 0.8 | 90 | 2 |
807.506 | - | - | - | - | - | - | - | - | - | - | 150 | 2.3 | 7 | 2 | |
836.207 | 1.2 | 1.5 | 2.5 | 25 | 1.6 | 59 | 2 | 1.3 | 1.3 | 59 | - | - | - | - |
Nutriline Twinflo is a 2Fr polyurethane double lumen central venous catheter for premature babies and neonates inserted in a peripheral vein (basilic, cephalic, saphena...).
It is particularly recommended for medium and long-term IV therapies (up to 4 weeks) and for the simultaneous administration of incompatible drugs.
Nutriline Twinflo is inserted through a 20G peelable plastic cannula (Microflash), the needle of which features a lateral eye to quickly visualize blood reflux after successful cannulation of the vein. The peelable cannula is totally removed after catheter placement.
For the stabilization of the catheter, Nutriline Twinflo is supplied with Grip-Lok device with hypoallergenic adhesive specially designed for Neonates.
A measuring tape is supplied for the user to measure the length of catheter to insert from the puncture site to the lower third of the superior vena cava.
Product benefits:
5 codes are available:
1252.225: Nutriline Twinflo 20 cm without stylet and with Microflash introducer
1252.230: Nutriline Twinflo 30 cm with stylet and with Microflash introducer
1252.232: Nutriline Twinflo 30 cm without stylet and without introducer
1252.233: Nutriline Twinflo 30 cm with stylet and without Microflash introducer
1252.235: Nutriline Twinflo 30 cm without stylet and with Microflash introducer
Quantity box/case: 10/50
| Introducer | Catheter | ||||||||||
Code | Type | Ext. Ø | Length | G | Length | Ext. Ø | Gauge | Flow rate (Pressure 1 bar) | Prim. vol. | Stylet | Ø | |
| 1252.225 | Microflash | 1.0 | 21 | 20 | 20 | 0.6 | 24 | 3.20 (x2) | 0.2 (x2) | No | 2 |
1252.230 | Microflash | 1.0 | 21 | 20 | 30 | 0.6 | 24 | 1.45 (x2) | 0.2 (x2) | Yes | 2 | |
1252.232 | Without introducer | - | - | - | 30 | 0.6 | 24 | 1.45 (x2) | 0.2 (x2) | No | 2 | |
1252.235 | Microflash | 1.0 | 21 | 20 | 30 | 0.6 | 24 | 1.45 (x2) | 0.2 (x2) | No | 2 |
Product Details:
Country of Origin | Made in India |
Catheter in radiopaque and transparent PUR, can be used for venous or arterial access.
Supplied with a small 2 way stopcock and identification plugs (red for arterial use, blue for venous use).
Actual distance from the distal tip is printed numerically from 4 to 25 cm.
| Catheter | ||||||
Code | Int. Ø | Ext. Ø | Ø | Length | Flow rate | Prim. vol. | |
| 1270.02 | 0.5 | 0.8 | 2.5 | 30 | 3 | 0.12 |
1270.03 | 0.8 | 1.2 | 3.5 | 40 | 10 | 0.27 | |
1270.04 | 0.8 | 1.5 | 4 | 40 | 10 | 0.29 | |
1270.05 | 1.0 | 1.7 | 5 | 40 | 23 | 0.40 | |
1270.08 | 1.5 | 2.5 | 8 | 40 | 100 | 0.81 |
Fr 2.5* (length 30 cm) - 3.5* (length 40 cm) - Quantity box/case: 8/120
* To be ordered under code number 1270.02 -1270.03.
Fr 4 - 5 - 8 -Length 40 cm - Quantity box/case: 20/180
Tracheal and bronchial suction catheter.
Open tip. Proximal connector with lateral eye for finger tip control (with integral closing cap).
Fr 4 – 5 – 6 – 7 – 8 – 10: with 2 lateral eyes
Centimetre graduations from 5 to 20 cm. Length 29 cm
Fr 12 – 14 – 16 – 18: no lateral eyes
Centimetre graduations from 5 to 20 cm. Length 42 cm
Quantity box/case: 50/450
| Tube | |||
Code | Length | Ext. Ø | Colour code | |
535.04 | 29 | 4 | - | |
535.05 | 29 | 5 | - | |
535.06 | 29 | 6 | - | |
535.07 | 29 | 7 | - | |
535.08 | 29 | 8 | - | |
535.10 | 29 | 10 | - | |
70565.05 | 56.5 | 5 | Grey | |
70565.06 | 56.5 | 6 | Light green | |
70565.07 | 56.5 | 7 | Pink | |
70565.08 | 56.5 | 8 | Blue | |
70565.10 | 56.5 | 10 | Black |
CAT.NO. |
DESCRIPTION |
64123-B |
Torque Device in Blue Handle |
64123-G |
Torque Device in Green Handle |
64123-O |
Torque Device in Orange Handle |
64123-Y |
Torque Device in Yellow Handle |
4.9/5